Skip to content

Conversion from "F" to "mK" erroneous #264

Open

Description

@martinsw

To get correct values for the conversion from "F" to "mK" I have to change this line in the UnitSystem.xml from
<UnitOfMeasure domainID="mK" scale="0.001" baseOffset="-0.27315">
to
<UnitOfMeasure domainID="mK" scale="0.001" baseOffset="-273.15">

Sample code to reproduce:
using RepresentationUnitSystem = AgGateway.ADAPT.Representation.UnitSystem;
...
private void erroneousConversion()
{
RepresentationUnitSystem.UnitOfMeasure sourceUOM = RepresentationUnitSystem.InternalUnitSystemManager.Instance.UnitOfMeasures["F"]; // Fahrenheit
// RepresentationUnitSystem.UnitOfMeasure targetUOM = RepresentationUnitSystem.InternalUnitSystemManager.Instance.UnitOfMeasures["K"]; // Kelvin
RepresentationUnitSystem.UnitOfMeasure targetUOM = RepresentationUnitSystem.InternalUnitSystemManager.Instance.UnitOfMeasures["mK"]; // Millikelvin
RepresentationUnitSystem.UnitOfMeasureConverter converter = new RepresentationUnitSystem.UnitOfMeasureConverter();
double convertedValue = converter.Convert(sourceUOM, targetUOM, 0); // 0° F == 255.4 K
System.Diagnostics.Debug.Print($"{convertedValue}");
convertedValue = converter.Convert(sourceUOM, targetUOM, 98.6); // 98.6° F == 310.1 K
System.Diagnostics.Debug.Print($"{convertedValue}");
}